High Temperature Blocking for Power Modules to 3000VDC

For large power modules with rated voltages up to 3000 VDC and drain source leakage currents up to 100 milliamps Alpha Automation has developed the HVHTB180. Each test device is mounted to an individually controlled heat stage allowing precise device by device temperate control even with leakage currents that vary widely across test lots. Stage temperature can be up to 175°C and provision is made for die temperature sensing by monitoring the forward voltage of a rectifier embedded in the test device.